| Operating Viscosities:
For petroleum-based fluids the optimal level is 150 SUS.
For continuous operations, the level should range from 60
to 5000 SUS.
Filtration:
A minimum of 10 micron (abs.) filtration is required. A return
line filter is preferred. Bypass filtration and suction filters/
strainers are not recommended. Fluid cleanliness should conform
to ISO 16/13 level.
Inlet Conditions and Piping:
The maximum temperature at the inlet should be 140º
F. For higher levels consult factory. Inlet pipe, hose or
tubing must be sized properly to limit resistance to <
6 in. Hg (3 psi). Suction hose, if used, must be wire reinforced
to prevent its collapse. All connections must be air-tight.
Case Drain:
Two case-drain ports are provided on all models. The case-drain
line must be properly sized to limit port back-pressure to
< 25 psi.
Tandem Pumps:
All side-ported models can be modified to tandem pumps by
adding a thru-drive shaft and a coupling. In addition, adapter
flanges can increase or reduce flange pilots. Consult factory
for details.
Pump approximate weight: 200 lbs. |