PVX 7112 Frame 3
Pump Specifications

FeaturesPerformanceDimensionsSpecificationsSelector System ChartDownload PDF
Rated Pressure Peak Pressure Minimum Pressure
3500 lb/in² (241 bar) 4250 lb/in² (293 bar) 500 lb/in² (34 bar)

 

Displacement Theoretical Flow
@ 1800 RPM
Maximum Speed
@ ATM. Pressure
Minimum Speed
7.0 in³/rev (112 cm³/rev) 54.5 gal/min (206.0 l/min) 2200 rpm 600 rpm

 

Input Torque @ Rated Pressure Shaft Size Recommended Torque Limit
3,900 in-lb (439.0 N-m) SAE C
SAE CC
5,500 in-lb (619.4 N-m)
9,500 in-lb (1070.0 N-m)

Input shaft torque should not exceed the total of front-pump torque and the added torque requirements of its rearmounted units. To calculate input torque at conditions other than rated, use:

TA = TR * ( PA / PR ) * (QA / QR )

Where:
TA=Actual torque, PA=Actual maximum pressure, QA=Actual flow, TR=Rated torque,
PR=Rated working pressure, QR=Rated flow

Terms and Conditions of Sale